Any feedback?
Please rate this page
(literature.php)
(0/150)

BRENDA support

Literature summary for 1.4.1.3 extracted from

  • Gomes, S.; Dolezalova, J.; Araujo, A.; Couto, C.; Montenegro, M.
    Glutamate sol-gel amperometric biosensor based on co-immobilised NADP + and glutamate dehydrogenase (2013), J. Anal. Chem., 68, 794-800 .
No PubMed abstract available

Application

Application Comment Organism
analysis development of a glutamate amperometric sol-gel biosensor. A carbon paste electrode is electrochemically modified with methylene green. NADP+ and glutamate dehydrogenase are coimmobilised in a sol-gel matrix. When coupled to a flow injection system, the biosensor shosd good electrocatalytic activity towards NADPH oxidation at a potential of + 0.3 V vs. Ag/AgCl. The biosensor yields a linear response from 50 microM to 10 mM glutamate, with a detection limit of 5 microM and reproducibility of results better than 2.3% Bos taurus

Organism

Organism UniProt Comment Textmining
Bos taurus
-
-
-

Source Tissue

Source Tissue Comment Organism Textmining
commercial preparation
-
Bos taurus
-
liver
-
Bos taurus
-