Literature summary for 1.20.9.1 extracted from

  • Male, K.B.; Hrapovic, S.; Santini, J.M.; Luong, J.H.
    Biosensor for arsenite using arsenite oxidase and multiwalled carbon nanotube modified electrodes (2007), Anal. Chem., 79, 7831-7837.
    View publication on PubMed

Application

Application Comment Organism
additional information biosensor for arsenite using molybdenum-containing arsenite oxidase, which is applicable for repeated analysis of spiked arsenite in tap water, river water, and commercial mineral water Rhizobium sp.

Metals/Ions

Metals/Ions Comment Organism Structure
Mo
-
Rhizobium sp.

Organism

Organism UniProt Comment Textmining
Rhizobium sp.
-
-
-
Rhizobium sp. NT-26
-
-
-

Purification (Commentary)

Purification (Comment) Organism
gel filtration Rhizobium sp.

Storage Stability

Storage Stability Organism
-80°C, 50 mM MES-buffer, pH 5.5, 100 mM NaCl Rhizobium sp.

Substrates and Products (Substrate)

Substrates Comment Substrates Organism Products Comment (Products) Rev. Reac.
arsenite + H2O + azurin(ox)
-
Rhizobium sp. arsenate + azurin(red)
-
?
arsenite + H2O + azurin(ox)
-
Rhizobium sp. NT-26 arsenate + azurin(red)
-
?